15.6" Venus, Intel Atom Z8350, 32GB eMMC, 2GB RAM, PCAP, DC12~24V / POE, Ubuntu 19.04 (Model: VPCW1560AO2-POE-L)

15.6" Venus, Intel Atom Z8350, 32GB eMMC, 2GB RAM, PCAP, DC12~24V / POE, Ubuntu 19.04

15.6" Venus, Intel Atom Z8350, 32GB eMMC, 2GB RAM, PCAP, DC12~24V / POE, Ubuntu 19.04

VPCW1560AO2-POE-L
  • Specifications
  • Download
Component
CPU Intel Atom Z8350
CPU Cooler (Type) Heatsink
Memory 2GB/4GB DDR3L
Power Supply DC Input, 12 ~ 24V/ Powered LAN 802.3AT
Microphone 1 x A-MIC
Speaker 2 x 4Ω 2.0W/2.5W(MAX) speaker(L & R)
Camera 2.0MP Camera
Wireless LAN WIFI 802.11 b/g/n
Operating System Windows10 IoT 2016 64bit / Android 5.1 64bit
Storage
Other Storage Device 32GB/64GB eMMC
Panel
LCD Panel 15.6", 1920x1080 pixel
Touch Screen PCAP
External I/O
Serial Port 1 x RJ45 for RS232/422/485(configurable by BIOS setting)
USB Port 2 x USB 2.0 Type A
LAN Port 1 x 10/100/1000 Ethernet
Indicator Light LED indicating bar
Others 1 x Headphone- 1 x 3.5mm Audio Jack (4 rings)
Mechanical
Power Type DC-IN(12~24V)/ Powered LAN 802.3T)
Power Connector Type DC-IN : DC Jack 5.7mm
Powered LAN+ : RJ45  
Dimension 472.1 x 269 x 70.1 mm
Weight 2.5kg
Color white
Option 1 x Handset
Software  
BIOS 64 bit
Reliability
EMI Test CE/ FCC class B
Dust and Rain Test Front Panel IP65
 
Vibration Test Sine Vibration test (Non-operation)
Reference IEC60068-2-6 Testing procedures
Test Fc : Vibration sinusoidal
1 Test Acceleration : 2G
2 Test frequency : 5~500 Hz
3 Sweep:1 Oct/ per one minute. (logarithmic)
4 Test Axis : X,Y and Z axis
5 Test time :30 min. each axis
6 System condition : Non-Operating mode
Package Vibration Test
Reference IEC60068-2-64 Testing procedures
Test Fh : Vibration boardband random Test
1. PSD: 0.026G2/Hz , 2.16 Grms
2. Non-operation mode
3. Test Frequency : 5-500Hz
4. Test Axis : X,Y and Z axis
5. 30 min. per each axis
Random Vibration Operation
Reference IEC60068-2-64 Testing procedures
Test Fh : Vibration boardband random Test
1. PSD: 0.00454G2/Hz , 1.5 Grms
2. Operation mode
3. Test Frequency : 5-500Hz
4. Test Axis : X,Y and Z axis
5. 30 minutes per each axis
6. IEC 60068-2-64 Test:Fh
Mechanical Shock Test Bump Test
Reference IEC 60068-2-29 Testing procedures
Test Eb : Bump Test
1. Wave form:Half Sine wave
2. Acceleration Rate:10g for operation mode
3. Duration Time:11ms
4. No. of Shock:Z axis 300 times
5. Test Axis: Z axis
6. Operation mode
Drop Test 1. One corner , three edges, six faces
2. ISTA 2A, IEC-60068-2-32 Test:Ed
Operating Temperature 0°C ~ 40°C
Operating Humidity 0% ~ 90% Relative Humidity, Non-condensing
Storage Temperature -20°C ~ 60°C