AMP1-SDA

1RU 2 Channels of SDI, AES and Analog (Model: AMP1-SDA)

1RU 2 Channels of SDI, AES and Analog (Model: AMP1-SDA)

AMP1-SDA
  • Overview
  • Specifications

The AMP1-SDA audio monitor provides self-powered, full-fidelity stereo monitoring in the smallest rack space possible (1U).

The unit features an SDI input and reclocked output on BNC connectors, AES input on a BNC connector, AES output (converted from the SDI input) on BNC connector, analog inputs on two balanced XLR connectors, SDI subgroup select switch, SDI/AES source switch, D/A source switch, and two high-resolution 26-segment tri-color LED bargraph level meters.

A pair of balanced XLR connectors output the selected audio source for connection to downstream equipment.

The level meters may be adjusted for a number of parameters, including Display Mode, Peak Hold, PPM Ballistics, Alternate Scales, and Phase Correlation via rear panel and internal DIP switches. An Auto Line Level Calibrate feature is also available.

The audio amplifier section features five high performance transducers driven by three power amplifiers: two amplifier/driver combinations handle midrange and high frequency information in stereo (left and right speakers), while the third center channel reproduces information below the 500 Hz crossover point (woofer speaker).

Output limiter circuits are incorporated to protect the speakers, and extensive magnetic shielding allows placement immediately adjacent to magnetically sensitive equipment, such as video monitors.

The unit front panel also features an AES status LED, an SDI status LED, Wohler's' proprietary three-LED stereo phase indication feature, volume control, balance pot, power indication LED, and stereo headphone output.

Specifications:
 
Rack Height: 1RU
Weight: 14.0 LBS (6.4 KG)
Dimensions: 1.75X19X12" (44.5X483X298MM)
Power Consumption: 35W
Signals Monitored: ANALOG;AES/EBU;SD-SDI
Analog Inputs: 2 BALANCED ANALOG INPUTS ON XLR
Analog Outputs: 2 BALANCED ANALOG OUTPUTS FROM AES OR SDI ON XLR
AES/EBU Inputs: 1 BALANCED AES INPUT PAIR ON BNC
AES/EBU Input Termination: 75 OHMS UNBALANCED
AES/EBU Input Sampling Rate: 32-48 KHZ, AUTO-DETECTING
AES/EBU Outputs: 1 UNBALANCED AES OUTPUT PAIR FROM SDI ON BNC
SDI Inputs: 1 SD-SDI INPUT ON BNC
SDI Input Termination: 75 OHMS UNBALANCED
SDI Outputs: 1 SD-SDI RECLOCKED OUTPUT ON BNC
Level Meters: 2 X 26 SEGMENT (VERTICAL)
Level Meter Scale: +12 TO -50 DB
Level Meter Threshold: 0, +4, +6, +8 DBV(='0'), DIP SELECTABLE; FACTORY SETTING IS +4 D
Level Meter Dynamics: SIMULTANEOUS VU & PPM
Level Meter Resolution: 2 DB
Aural Sound Outputs: WOHLER SPEAKER SYSTEM;HEADPHONE, MUTES SPEAKERS
Acoustic Distortion: 8% OR LESS AT WORST CASE FREQUENCIES ABOVE 180 HZ INCLUDING CABINET RESONANCE, TYPICALLY < 2%
Electrical Distortion: <0.15% AT ANY LEVEL BELOW LIMIT THRESHOLD
Frequency Response (1/6 octave): 80 HZ - 16 KHZ (+ OR -7 DB); (-10 DB @ 50 HZ, 22 KHZ)
Peak Acoustic Output @ 2 feet: 98 DB SPL
Hum and Noise: BETTER THAN -68 DB BELOW FULL OUTPUT