Easy evaluation of DICOM GSDF conformance and high luminance.
High luminance model best suited for color medical images whose increased use is expected; equipped with a hardware pivot function for fast drawing in portrait orientation.
Features
Newly developed luminance stabilizing system λ-Sentinel II
Provides enhanced stability in luminance and interaction with performance monitoring software PM Medivisor to evaluate conformity to DICOM GSDF.
Luminance stabilizing system to provides continuous stable display for medical images
A change in luminance affects gamma characteristics and therefore has adverse effects on diagnostic imaging. TOTOKU'smedical image displays are equipped with a luminance stabilizing system that automatically compensates for luminance changes due to startup drift, temperature change, and aging.
Features
- With luminance fluctuation caused by the LCD module taken into account, highly accurate luminance control is achieved.
- Actual luminance measurements including intermediate luminance are taken on the screen surface.
- Build-in luminance sensor provided with i2 models enables even simpler calibration without attaching the calibration sensor.
Note: λ-Sentinel II module is built into the the ME/CCL Series i model displays. Other models are equipped with λ-Sentinel (TOTOKU's conventional system).
High luminance, high quality LCD panel
Provides high quality images with maximum luminance of 400cd/m² and contrast ratio of 400:1. Due to its wide dynamic range, high quality grayscale is achieved.
Color calibration function to reproduce colors faithful to the original and grayscale compliant with DICOM Part 14
By calibrating color temperature, luminance, and gamma characteristics, reproduction of colors faithful to the original and smooth display of grayscale are possible.
Calibration function to accurately adjust gamma, color temperature, and luminance
Medical image displays are commonly required to display grayscale according to the Grayscale Standard Display Function (GSDF) defined by DICOM Part 14. The calibration function creates the optimum conditions for a medical imaging display by adjusting luminance levels, color temperature, and grayscale characteristics to achieve DICOM GSDF compliant grayscale output.
Models supported: All ME/CCL Series models, except ME183L and CCL192 plus
Note: Calibration requires an optional calibration kit*
How it works
The calibration function corrects the driving level of the LUT (Look-up Table), a memory that specifies the LCD driving, and writes it in the LUT. In other words, calibration adjusts grayscale characteristics, color temperature (color displays only), and luminance.
The luminance for each driving level is corrected such that the resulting curve matches the DICOM GSDF achieving smooth grayscale output.
Graph is for explanatory purpose only.
* Calibration kit (optional)
Package contents
- Calibration software: Medivisor for i2 Series, Medivisor Grayscale, Medivisor Color, Medivisor for ME201L/ME181L
- QA Medivisor
- Utility Software for i2 Series
- GSDF Checker
- Luminance sensor
|
|
Built-in 10bit LUT (Look-up Table) to reproduce beautiful grayscale
The built-in LUT selects the most appropriate 256 shades of gray (8bit) out of 1024 shades (10bit) to realize finer and smoother grayscale.
Built-in LUT (Look-up Table) to reproduce beautiful grayscale and TOTOKU's technology for simultaneous display of multiple shades
General-purpose displays are capable of 256 shades of gray, but due to unevenness and grayscale discontinuity, they cannot reproduce and display the subtle shading difference required for medical image displays. TOTOKU's medical image displays display the most appropriate 256 shades (8bit) out of a maximum of 12241 shades of gray using the built-in LUT. This technology realizes much finer and smoother grayscale than possible with general-purpose displays.
Moreover, combining with a TOTOKU display customized conversion table with an integrated viewer, up to 2048 shades of gray can be provided to produce film-like images on the display.
DICOM GSDF compliant curves according to the number of simultaneously available gray shades
* Images are provided for explanatory purposes only.
Hardware based pivot function to enable high speed drawing in portrait orientation
The pivot function allows for a 90-degree rotation of the LCD panel into portrait orientation. Unlike other pivoting functions that are implemented using graphics cards and/or that require special software, TOTOKU's hardware pivot function is directly implemented in display hardware, and thus it is much faster with less noise.
OSD Information Display
Such information as the display model, total operating time, actual measurement of luminance, and calibration settings can be checked on screen.
LED indicator to inform of current status
A glance at the LED indicator tells you the display's current operating status in three distinct colors. When in normal mode (luminance is stabilized), the LED is not lighted to minimize negatively impacting the diagnostic interpretation.
Models supported
All i2 and i models |
Worldwide medical safety standards
This display is certified under various medical safety standards that are much more demanding than those for general-purpose IT equipment.
Specifications
Model Name |
CCL350i |
LCD |
Technology |
20.8-inch, Color, TFT active matrix |
Display Area |
423.9mm x 318.0mm |
Pixel Pitch |
0.207mm x 0.207mm |
Contrast Ratio |
400:1 (typ) |
Maximum Luminance |
400cd/m² (typ), (factory-set to 200cd/m²) |
Viewing Angle |
170° horizontal and vertical (typ) |
Visual Performance |
Available Resolution |
USTEXT, 640 x 480 (VGA), 800 x 600 (SVGA), 1024 x 768 (XGA), 2048 x 1536 (QXGA) |
Color Display |
Full color (16.77 million colors) |
Input Signal |
Input Sync Signal |
DVI 1.0 compliant |
Plug and Play |
DDC2B compliant |
Input Power Supply |
Input |
AC Adapter 100V-240V (±10%) 50/60Hz |
Maximum Power Consumption |
83W (typ), (with power management feature) |
Features |
Calibration Control |
Luminance, Gamma, Color temp., Capability to save 3 sets of LUT settings (A calibration kit is required.) |
OSD Information Display |
Model name, Serial No., Total operating time, Calibration settings (Operating time since the last calibration, Luminance, Gamma, Color temp., etc.), Current luminance, etc. |
USB Hub |
USB Rev. 2.0 compliant, Self-powered
USB upstream connector (x1), USB downstream connector (x2) |
Other Features |
Hardware pivot, LED indicator |
Standards |
UL60601-1, CSA C22.2 N601.1, MDD/CE, FDA 510(k), CCC, MIC, BSMI, FCC-B, VCCI-B |
Physical Characteristics |
Dimensions (WxHxD) |
Landscape: 474mm x 468.4/529.9mm x 220mm
Portrait: 367mm x 521.9/583.4mm x 220mm |
Weight |
Approx. 11kg (Approx. 6.8kg without tilt stand) |
Tilt Stand |
Tilt, swivel, landscape/portrait rotation |
Mount |
100mm VESA compliant |
Security Slot |
Antitheft security slot (Panel and tilt stand) |
Protective Filter |
Antireflection-coated protective filter |
Accessories |
AC adapter, 3P power cord, DVI cable, Serial cable, USB cable, User manual |
Dimensions