-40 ℃ Cold Start Test

 

LMilW1560 is a 15.6" PCAP Full HD Panel PC with i3-6100U, IPS Wide Viewing Angle and 1600nits Backlight.

 
LMilW1560 - Cold start testing (1st time 2 hours)

 
LMilW1560 - Cold start testing (2nd time 4 hours)
 
 

LMilW1560 Cold Start Test Report

 

1 Test Conditions

 
1.1 Environmental Conditions
Chamber: TERCHY_MHK-408LK
 
1.2 Product General Descriptions
15.6" PCAP Panel PC
Model No.: LMilW1560
OS Windows 10 Enterprise 2016 L TBS
CPU Intel Core i3-6100U CPU@ 2.30GHz
Memory 4GB
Power Supply EDACPOWER: EA10951F-120 OUTPUT: 12V
 

1.3 Test Specifications

1. First Stage:
First cool down to -40°C, let stand 2 hours and then turn it on by manual. Manual operation and running Burning Test, run for 1 minute and then shut down.
Step Temperature Duration Remark
0 25°C 0H00M Chamber-ON
1 -40°C 2H00M 25°C cool down to -40°C
2 -40°C 2H00M  
 
2. Second Stage
First cool down to -40°C, let stand 4 hours and then turn it on by manual. Manual operation and running Burning Test, run for 1 minute and then shut down.
Step Temperature Duration Remark
0 25°C 0H00M Chamber-ON
1 -40°C 2H00M 25°C cool down to -40°C
2 -40°C 2H00M  
 

2 Test Result

First stage test results: PASS
Second stage test results: PASS